ARTÍCULOS MÉDICOS

Mano y muñeca

Rotational stability in screw-fixed scaphoid fractures compared to plate-fixed scaphoid fractures

Archives of Orthopaedic and Trauma Surgery

November 2016, Volume 136, Issue 11, pp 1623–1628

Rotational stability in screw-fixed scaphoid fractures compared to plate-fixed scaphoid fractures

  • Josef Jurkowitsch(1); E. Dall’Ara (2); S. Quadlbauer (,3,4) ; Ch. Pezzei (1); I. Jung (3); D. Pahr (5); M. Leixnering (1).
  1. 1.AUVA Trauma Hospital Lorenz Böhler–European Hand Trauma CentreViennaAustria
  2. 2.Department of Oncology and Metabolism and Insigneo Institute for in Silico MedicineUniversity of SheffieldSheffieldUK
  3. 3.Ludwig Boltzmann Institute for Experimental und Clinical TraumatologyAUVA Research CenterViennaAustria
  4. 4.Austrian Cluster for Tissue RegenerationViennaAustria
  5. 5.Institute of Lightweight Design and Structural Biomechanics (ILSB)Vienna University of TechnologyViennaAustria

Cite this article as:
Jurkowitsch, J., Dall’Ara, E., Quadlbauer, S. et al. Arch Orthop Trauma Surg (2016) 136: 1623. doi:10.1007/s00402-016-2556-z

Abstract

Background

The literature describes the treatment of scaphoid fractures comparing the volar and dorsal approaches, the advantages and disadvantages of percutaneous screw fixation, as well as the treatment of scaphoid nonunions using different types of cancellous or corticocancellous bone grafts. Yet, to date no studies are available comparing the outcome of rotational stability in screw-fixed scaphoid fractures to angular stable systems. The purpose of this study is to provide reliable data about rotational stability in stabilised scaphoid fractures and to gain information about the rigidity and the stability of the different types of fixation.

Methods

Three groups of different stabilisation methods on standardised scaphoid B2 fractures were tested for rotational stability. Stabilisation was achieved using one or two cannulated compression screws (CCS) or angular stable plating. We performed ten repetitive cycles up to 10°, 20° and 30° rotation, measuring the maximum torque and the average dissipated work at angle level.

Results

Our study showed that rotational stability using a two CCS fixation is significantly (p < 0.05) higher than single CCS fixation. Using the angular stable plate system was also superior to the single CCS (p < 0.05). There was, however, no significant difference between two CCS fixation and angular stable plate fixation.

Conclusion

Even though indications of using screws or plate systems might be different and plate osteosynthesis may be preferable in treatment of dislocated or comminuted fractures as well as for nonunions, our study showed a better rotational stability by choosing more than just one screw for osteosynthesis. Angular stable plating of scaphoid fractures also provides more rotational stability than single CCS fixation. The authors therefore hypothesise higher union rates in scaphoid fractures using more stable fixation systems.

Introduce tu búsqueda en el cajetín para encontrar contenido.

Ir al contenido