ARTÍCULOS MÉDICOS

Hombro y codo

Coracoclavicular stabilization using a suture anchor technique

NULL

Am J Orthop. 2008 Jun;37(6):294-300. Friedman DJ, Barron OA, Catalano L, Donahue JP, Zambetti G. Multiple fixation options exist for coracoclavicular stabilization, but many are technically demanding and require hardware removal. In the study reported here, we reviewed a specific fixation technique that includes suture anchors moored in the base of the coracoid process. We retrospectively reviewed 24 consecutive cases of patients who underwent coracoclavicular stabilization with a suture anchor for a type III or type V acromioclavicular (AC) joint separation or a group II, type II or type V distal clavicle fracture. Eighteen of the 22 patients had full strength and painless range of motion (ROM) in the affected extremity by 3 months and at final follow-up (minimum, 24 months; mean, 39 months). Two patients were lost to follow-up. Four patients had early complications likely secondary to documented noncompliance. Two of these 4 patients underwent reoperation with a similar procedure and remained asymptomatic at a minimum follow-up of 15 months. One patient underwent osteophyte and knot excision 7 months after surgery and remained asymptomatic at 30 months. Our results suggest that coracoclavicular stabilization using a suture anchor technique is a safe and reliable method of treating acromioclavicular joint separations and certain distal clavicle fractures in the compliant patient.

Introduce tu búsqueda en el cajetín para encontrar contenido.